Evidence report: warehouse_amr_1

Evidence of declared intent and its checks. Not a safety assessment, a certification or a compliance determination.

As of 2026-11-24 · urml-validator 0.5.2 · profiles: warehouse · policy: bundled

Summary

StatusItemsMeaning
checked21The validator checks this before a program runs.
declared9Someone states this; URML records who and does not verify it.
runtime4The runtime must enforce this while a program runs.
missing1Something a rule, the policy or the envelope needs is absent.
outside15URML cannot see this; someone else must cover it.

Gaps: 2 (1 missing, 1 failed check).

Gaps

Robot

StatusItemWhat the report knows
checkedcapability.mobilityMobility (differential), up to 1.5 m/s. The validator refuses steps faster than this or the envelope's limit. No evidence tag: the claim's source is not recorded.
checkedcapability.gripper.robotiq_2f85Gripper robotiq_2f85 (servo_electric), 1 to 235 N. The validator refuses grasps above the maximum or the envelope's limit. No evidence tag: the claim's source is not recorded.
checkedcapability.camera.front_rgbdCamera front_rgbd. Capture steps must name a declared camera. No evidence tag: the claim's source is not recorded.
checkedcapability.sensor.front_lidarSensor front_lidar (distance). No evidence tag: the claim's source is not recorded.
checkedcapability.sensor.batterySensor battery (voltage). No evidence tag: the claim's source is not recorded.

Provenance

StatusItemWhat the report knows
declaredprovenance.attestationManifest attestation: self_declared.
declaredcomponent.amr_baseComponent amr_base (critical): vendor clearpath, origin CA, final assembly CA.
declaredcomponent.arm_controllerComponent arm_controller (critical): vendor universal_robots, origin DK, final assembly DK.
declaredcomponent.gripperComponent gripper (non_critical): vendor robotiq, origin CA, final assembly CA.
declaredcomponent.head_cameraComponent head_camera (critical): vendor intel, origin US, final assembly US.
declaredcomponent.front_lidarComponent front_lidar (critical): vendor ouster, origin US, final assembly US.
checked, passpolicy_rule.critical_country_denylistPolicy rule critical_country_denylist: passed.
checked, passpolicy_rule.critical_final_assembly_denylistPolicy rule critical_final_assembly_denylist: passed.
checked, passpolicy_rule.covered_vendor_denylistPolicy rule covered_vendor_denylist: passed.
checked, passpolicy_rule.hbom_required_for_criticalPolicy rule hbom_required_for_critical: passed.
checked, passpolicy_rule.attestation_floorPolicy rule attestation_floor: 1 finding (warning). Self-declared provenance accepted in v0.1 but flagged. v0.2 will promote this to an error; deployments should arrange third-party attestation now.

Envelope

StatusItemWhat the report knows
checkedlimit.max_velocityThe envelope limits speed to 1 m/s. The manifest allows 1.5 m/s; the stricter, 1 m/s, applies.
checkedlimit.max_payloadThe envelope limits payload to 50 kg.
checkedlimit.max_grip_force_nThe envelope sets no grip force limit; the manifest's 235 N applies.
checkedgeofence.hall_2Geofence hall_2 (frame site, 4 vertices). Every place a program names must lie inside a declared geofence.
checkedpeople_zone.break_areaPeople-occupancy zone break_area (frame site). Programs may not target places inside it.
runtimeruntime.start_positionWhere the robot starts. The runtime must not start a program while the robot is outside every geofence, or inside a people-occupancy zone that does not allow an override.
runtimeruntime.pathsThe path between two checked places. The runtime must keep it inside the geofences and out of the people-occupancy zones.
runtimeruntime.unstated_speedThe speed of a step that states none. The runtime must keep it at or below the strictest speed limit.
runtimeruntime.emergency_stopOn an emergency stop reported by the substrate, the runtime must stop dispatching and stop every motion it commands. The emergency stop itself is a function of the machine.

Rules

StatusItemWhat the report knows
checkedrule.hall_2_amr_rules.max_travel_speedMaximum travel speed a program may request. Checked against every program (cap).
checkedrule.hall_2_amr_rules.outside_operating_zonesPrograms never send a robot outside its operating zones. Checked against every program (forbid_zone_entry).
checkedrule.hall_2_amr_rules.load_handling_at_stations_onlyLoads are picked and placed only at designated stations. Checked against every program (forbid_primitive).
checkedrule.hall_2_amr_rules.validated_programs_onlyOnly robot programs covered by the risk assessment run. Checked against every program (forbid_primitive).
checkedrule.hall_2_amr_rules.safety_outputs_untouchedPrograms never write safety-related output lines. Checked against every program (forbid_primitive).
outsideobligation.hall_2_amr_rules.risk_assessmentA current risk assessment for the mobile robot system. The site has a risk assessment that covers every route, station and task these programs use, repeated whenever the layout, the fleet or the tasks change.
outsideobligation.hall_2_amr_rules.safety_rated_functionsPersonnel detection and stopping in safety-rated control. Personnel detection, speed control near people, braking and emergency stop run in the robot's safety-rated hardware and software, at the performance levels the standards require, not in URML and not in the fleet manager.
outsideobligation.hall_2_amr_rules.zones_marked_and_declaredOperating and restricted zones are marked on site and match the manifest. The zones the risk assessment defines are marked on the floor or otherwise identified, and the declared_areas in each robot's manifest are drawn to match them.
outsideobligation.hall_2_amr_rules.system_validationThe installed system is verified and validated before use. The integrator verifies and validates the safety functions of the installed mobile robot system before the site runs production programs.
outsideobligation.hall_2_amr_rules.users_trainedPeople who work near the robots are trained and informed. The site operator trains the people who work with or near the robots, keeps the information for use current, and keeps zones clear as the risk assessment requires.
declaredrule.hall_2_safety.emergency_stop_declaredThe emergency stop's safety level is declared and meets its requirement. Declared emergency_stop_safety_level: PLd, by hall_2_safety_declarations. URML checks the declaration is there and allowed, not that it is true.
declaredrule.hall_2_safety.protective_stop_declaredThe protective stop's safety level is declared and meets its requirement. Declared protective_stop_safety_level: SIL2, by hall_2_safety_declarations. URML checks the declaration is there and allowed, not that it is true.
missingrule.hall_2_safety.speed_monitoring_declaredSafety-rated speed monitoring is declared and meets its requirement. The deployment declares no speed_monitoring_safety_level; every program is refused until it does.
declaredrule.hall_2_safety.safety_validation_on_recordThe safety functions' validation is on record. Declared safety_validation_record: VAL-2026-017, by hall_2_safety_declarations. URML checks the declaration is there and allowed, not that it is true.
outsideobligation.hall_2_safety.urml_is_not_a_safety_functionNothing in URML counts toward a performance level or a SIL. The URML validator and runtimes are not safety-related parts of the control system. They are left out of every performance level and safety integrity level calculation, and no safety function depends on them.
outsideobligation.hall_2_safety.urml_cannot_interfereURML cannot interfere with safety-related software. If URML runs on hardware that also runs safety-related software, the integrator shows that URML cannot interfere with it, or treats URML as safety-related, which URML does not support. The simpler design keeps URML on separate hardware.
outsideobligation.hall_2_safety.safety_functions_designedEach safety function is designed to its required level. Each safety function the risk assessment calls for is specified, designed and implemented in safety-related control to reach its required performance level or safety integrity level.
outsideobligation.hall_2_safety.safety_functions_validatedEach safety function is validated. The safety functions are validated before use, and again after any change to the safety-related control, and the validation record is kept.
outsideobligation.hall_2_safety.declarations_kept_trueThe declarations match the validation records. The operator keeps the deployment rulebook's declarations in line with the current validation records, and updates them when the safety functions or their validation change.

Programs

StatusItemWhat the report knows
checked, failvalidated.pick-to-conveyorProgram pick-to-conveyor.urml.yaml is refused, 1 error. rule.declaration_missing: ISO 13849-1:2023, IEC 62061:2021 or IEC 61508:2010, clause n.n (from a licensed copy); the machine's risk assessment: safety-rated speed monitoring is declared and meets its requirement. The deployment declares no speed_monitoring_safety_level (allowed: PLd, PLe, SIL2, SIL3, SIL4).

Conformance

No conformance report or registry entry was given.

Outside URML

StatusItemWhat the report knows
outsideoutside.safety_controlThe robot's safety-related control and its safety functions (stops, speed and separation monitoring, power and force limiting), designed and validated outside URML.
outsideoutside.below_substrateFirmware, controllers and drivers below the substrate.
outsideoutside.siteWiring, guarding and the physical site.
outsideoutside.declarationsWhether any declared item in this report is true.
outsideoutside.unmediatedAnything a program does through a path that does not pass through a URML runtime.

By standard

Standardcheckeddeclaredruntimemissingoutside
ANSI/A3 R15.08-1-202000001
ANSI/A3 R15.08-2-202350003
ANSI/A3 R15.08-3-202600001
IEC 61508-3:201000001
IEC 61508:201003014
IEC 62061:202103014
ISO 13849-1:202302012
ISO 13849-201002
ISO 3691-4:202340005

Inputs

RoleIdFileDigest
manifestwarehouse_amr_1manifest.yamlsha256:b54b3c140d171ebf5a7797e31f5756f3823e3ad81c8866735e9f45f67bf27e98
envelopewarehouse_hall_2envelope.yamlsha256:3ed0e01427fc9a2fa85266877740468fac599b2470f8d562f4f1645197dbaf3a
policyurml_us_federal_defaultbundledsha256:281e91ec5795a8d27cf029bb641704642eb8fb9e6dbb258ebbe2879ff960c4aa
rulebookhall_2_amr_rulesamr-rules.yamlsha256:2552e2a9e448e7e1695f8142cd6fdf492ab9a9dc33368824ce38c7825155ace7
rulebookhall_2_safetyfunctional-safety.yamlsha256:f6eeab13e8445e02df9d7d414803d05f6b049594228afe2aa355ae766718ae52
rulebookhall_2_safety_declarationsdeclarations.yamlsha256:bc6bce8c42e810a4dd90d7b4c56c49b3b95baa201a9c23a3a0347c4e1ee05f10
programpick-to-conveyor.urml.yamlsha256:ea3d21520cfe0bffac6a8218b725bee0f33fc3c8cc48a0fa1194ad483e5a8364

Rebuild this report from the same files with urml evidence build and the same --as-of date, and compare digests.